The miniature Flow Meter FC04 is designed to operate with air, compressed air, oxygen and nitrogen. Sensor head integral with electronic circuitry.
When used in a compressed-air system, the FC04 has to be installed behind the air dryer to prevent moisture condensation of the sensors. Damage of the ceramic sensors through particles in the pipe system must be prevented by suitable filtering measures.
Features(特征):
• Pressure resistant to 16 bar/232 psi
• Easy fitting by sensor adapter TP-... or ball valve BV-...
• Electrical Connection by means of M8 connectors following IEC 60947-5-2
• Measuring range factory preset to standard flow No moving parts in the flow stream • Response time < 1 s Quantity scaled pulse
FC04 | 传感器转接头TP/球阀 BV
Description(描述):
Sensor adapters TP and ball valves BV facilitate correct positioning and exchange of CSP monitoring heads, FC03, FC04 or FS10-U1...11 (plug- in type connection) in pipes with process connection DN
15...DN 50. Ball valve BV enables pressure-free installation or removal of CSP moni- toring heads,
Flow Meter FC03, FC04 and Flow Monitor FS10-U1...11 (plug-in type connection) simply by
closing the input and output pipe. The measuring points are suited to temporary measurements; after completion of the measuring cycle they can be closed by means of blanking plugs.
Features(特征):
•Correct positioning of sensor
•Ease of sensor replacement
•Measuring point can be closed if not used
•Sensor adapter available as screw-in or welding type
•Ball valve also serves as a shutoff valve (both input and output)
FC04 | 原装线缆
Description(描述):
Connection cable M12 for flow meter FC04 for connection of supply voltage and output signal.